Would anti-choking devices be correctly and quickly managed by health science students? A manikin crossover trial

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Didácticas Aplicadas
dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Psiquiatría, Radioloxía, Saúde Pública, Enfermaría e Medicina
dc.contributor.authorCardalda Serantes, Borja
dc.contributor.authorCarballo Fazanes, Aida
dc.contributor.authorRodríguez Ruiz, Emilio
dc.contributor.authorAbelairas Gómez, Cristian
dc.contributor.authorRodríguez Núñez, Antonio
dc.date.accessioned2025-10-29T10:06:01Z
dc.date.available2025-10-29T10:06:01Z
dc.date.issued2023-05-23
dc.description.abstractBackground: The brand-new anti-choking devices (LifeVac® and DeCHOKER®) have been recently developed to treat Foreign Body Airway Obstruction (FBAO). However, the scientific evidence around these devices that are available to the public is limited. Therefore, this study aimed to assess the ability to use the LifeVac® and DeCHOKER® devices in an adult FBAO simulated scenario, by untrained health science students. Methods: Forty-three health science students were asked to solve an FBAO event in three simulated scenarios: 1) using the LifeVac®, 2) using the DeCHOKER®, and 3) following the recommendations of the current FBAO protocol. A simulation-based assessment was used to analyze the correct compliance rate in the three scenarios based on the correct execution of the required steps, and the time it took to complete each one. Results: Participants achieved correct compliance rates between 80-100%, similar in both devices (p = 0.192). Overall test times were significantly shorter with LifeVac® than DeCHOKER® device (36.6 sec. [31.9-44.4] vs. 50.4 s [36.7-66.9], p < 0.001). Regarding the recommended protocol, a 50% correct compliance rate was obtained in those with prior training vs. 31.3% without training, (p = 0.002). Conclusions: Untrained health science students are able to quickly and adequately use the brand-new anti-choking devices but have more difficulties in applying the current recommended FBAO protocol.
dc.description.peerreviewedSI
dc.identifier.citationCardalda-Serantes, B., Carballo-Fazanes, A., Rodríguez-Ruiz, E., Abelairas-Gómez, C., & Rodríguez-Núñez, A. (2023). Would anti-choking devices be correctly and quickly managed by health science students? A manikin crossover trial. BMC Medical Education, 23(1), Article 365. https://doi.org/10.1186/s12909-023-04345-7
dc.identifier.doi10.1186/s12909-023-04345-7
dc.identifier.issn1472-6920
dc.identifier.urihttps://hdl.handle.net/10347/43485
dc.issue.number1
dc.journal.titleBMC Medical Education
dc.language.isoeng
dc.page.initial365
dc.publisherSpringer Nature
dc.relation.publisherversionhttps://doi.org/10.1186/s12909-023-04345-7
dc.rights© The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectAirway clearance
dc.subjectFBAO
dc.subjectLifeVac
dc.subjectDeCHOKER
dc.subjectNursing and medical students
dc.subjectSimulation
dc.subject.classification321305 Cirugía de garganta, nariz y oídos
dc.titleWould anti-choking devices be correctly and quickly managed by health science students? A manikin crossover trial
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number23
dspace.entity.typePublication
relation.isAuthorOfPublication3c449fb2-7714-4215-8e97-6580b9ceefdc
relation.isAuthorOfPublicatione7e9a9aa-84aa-4fe3-8916-db9bc30df040
relation.isAuthorOfPublication97e9bbde-8767-4063-87b7-fd3d7a288fa3
relation.isAuthorOfPublicatione7e9a9aa-84aa-4fe3-8916-db9bc30df040
relation.isAuthorOfPublicatione7e9a9aa-84aa-4fe3-8916-db9bc30df040
relation.isAuthorOfPublication.latestForDiscovery3c449fb2-7714-4215-8e97-6580b9ceefdc

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2023_BMCmedEduc_Cardalda_Anti-choking.pdf
Size:
936.96 KB
Format:
Adobe Portable Document Format