Estrus Detection and Optimal Insemination Timing in Holstein Cattle Using a Neck-Mounted Accelerometer Sensor System

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Patoloxía Animal
dc.contributor.affiliationUniversidade de Santiago de Compostela. Instituto de Biodiversidade Agraria e Desenvolvemento Rural (IBADER)
dc.contributor.authorÁlvarez Torres, Jacobo
dc.contributor.authorAcción Carro, Antía
dc.contributor.authorLópez, Elio
dc.contributor.authorAntelo, Carlota
dc.contributor.authorBarrionuevo, Renato
dc.contributor.authorBecerra González, Juan José
dc.contributor.authorPeña Martínez, Ana Isabel
dc.contributor.authorGarcía Herradón, Pedro José
dc.contributor.authorQuintela Arias, Luis Ángel
dc.contributor.authorYáñez, Uxía
dc.date.accessioned2025-10-20T10:24:51Z
dc.date.available2025-10-20T10:24:51Z
dc.date.issued2025-08-23
dc.description.abstractThis study aimed to evaluate the accuracy of the accelerometer-equipped collar RUMI to detect estrus in dairy cows, establish a recommendation for the optimal timing for artificial insemination (AI) when using this device, and characterize the blood flow of the dominant follicle (F) and the corpus luteum (CL) as ovulation approaches. Forty-seven cycling cows were monitored following synchronization with a modified G6G protocol, allowing for spontaneous ovulation. Ultrasound examinations were conducted every 12 h, starting 48 h after the second PGF2α dose, to monitor uterine and ovarian changes. Blood samples were also collected to determine serum progesterone (P4) levels. Each cow was fitted with a RUMI collar, which continuously monitored behavioral changes to identify the onset, offset, and peak of activity of estrus. One-way ANOVA assessed the relationship between physiological parameters and time before ovulation. Results showed that the RUMI collar demonstrated high specificity (100%), sensitivity (90.90%), and accuracy (93.62%) for estrus detection. The optimal AI window was identified as between 11.4 and 15.5 h after heat onset. Increased blood flow to the F and reduced luteal activity were observed in the 48 h prior to ovulation. Further research is needed to assess the influence of this AI window on conception rates, and if it should be modified considering external factors.
dc.description.peerreviewedSI
dc.description.sponsorshipJ.A. holds a predoctoral contract funded by the Fundación Caixa Rural Tomás Notario Vacas (2024 call). U.Y. holds a postdoctoral contract funded by the Xunta de Galicia (Ref. ED481_033/2024).
dc.identifier.citationÁlvarez, J.; Acción, A.; López, E.; Antelo, C.; Barrionuevo, R.; Becerra, J.J.; Peña, A.I.; Herradón, P.G.; Quintela, L.Á.; Yáñez, U. Estrus Detection and Optimal Insemination Timing in Holstein Cattle Using a Neck-Mounted Accelerometer Sensor System. Sensors 2025, 25, 5245. https://doi.org/10.3390/s25175245
dc.identifier.doi10.3390/s25175245
dc.identifier.issn1424-8220
dc.identifier.urihttps://hdl.handle.net/10347/43286
dc.issue.number17
dc.journal.titleSensors
dc.language.isoeng
dc.page.initial5245
dc.publisherMDPI
dc.relation.publisherversionhttps://doi.org/10.3390/s25175245
dc.rights© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. Attribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectDairy cattle
dc.subjectHeat detection
dc.subjectPrecision livestock farming
dc.subjectReproductive performance
dc.subjectUltrasonography
dc.titleEstrus Detection and Optimal Insemination Timing in Holstein Cattle Using a Neck-Mounted Accelerometer Sensor System
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number25
dspace.entity.typePublication
relation.isAuthorOfPublication31f5f7a1-42af-4131-b1f9-238f9d1b15e9
relation.isAuthorOfPublication6eb02ec2-b3db-43c3-b4f4-e7eea5a4b2f4
relation.isAuthorOfPublication53866ec7-2efa-489d-aba0-6006454f4c1e
relation.isAuthorOfPublication57ec282e-f2ed-4fb1-95b8-a06a89fb1f27
relation.isAuthorOfPublicationf68ec9ff-9257-4938-a079-83535b714a92
relation.isAuthorOfPublicationf68ec9ff-9257-4938-a079-83535b714a92
relation.isAuthorOfPublication.latestForDiscovery31f5f7a1-42af-4131-b1f9-238f9d1b15e9

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sensors 2025_25(17),5245.pdf
Size:
628.98 KB
Format:
Adobe Portable Document Format