Impedimetric Biosensor Based on a Hechtia argentea Lectin for the Detection of Salmonella spp.
Loading...
Identifiers
Publication date
Advisors
Tutors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
MDPI
Abstract
A sensitive electrochemical detection method for Salmonella spp. was described, based on the use of Hechtia argentea lectin immobilised on a screen-printed gold electrode. The lectin was extracted from Hechtia argentea, a plant belonging to the Bromeliaceae family. The lectin with molecular weight near 27.4 kDa showed selectivity towards D-mannose, contained on the lipopolysaccharide cell wall of Salmonella spp. Carbohydrate selectivity of the lectin was measured as a change in impedance with respect to concentration. The binding of the bacteria to the biosensor surface increased impedance with increasing concentrations of Salmonella spp., achieving a linear range of detection of 15–2.57 × 107 CFU mL−1, with a limit of detection of 5 CFU mL−1. Increases in impedance were measured using electrochemical impedance spectroscopy and analysed using Nyquist plots. The biosensor was applied in analysis of hen egg samples, and the results were consistent with those obtained using the official analysis methodology
Description
Bibliographic citation
Lopez-Tellez, J.; Sanchez-Ortega, I.; Hornung-Leoni, C.T.; Santos, E.M.; Miranda, J.M.; Rodriguez, J.A. Impedimetric Biosensor Based on a Hechtia argentea Lectin for the Detection of Salmonella spp.. Chemosensors 2020, 8, 115
Relation
Has part
Has version
Is based on
Is part of
Is referenced by
Is version of
Requires
Publisher version
https://doi.org/10.3390/chemosensors8040115Sponsors
Rights
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/)
Atribución 4.0 Internacional
Atribución 4.0 Internacional