Development and application of an LC-MS/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS)

Research Projects

Organizational Units

Journal Issue

Abstract

Therapeutic drug monitoring (TDM) of antiepileptic drugs (AEDs) is used for optimization and individualization of patients′ treatment. Capillary microsampling techniques are a promising alternative to conventional venous sampling for TDM. Both dried blood spots (DBS) and volumetric adsorptive microsampling (VAMS) devices are less invasive and patient-friendly sampling techniques which have been gaining interest in the last years. This study describes the development and validation of an LC-MS/MS method for the determination of 8 AEDs (Carbamazepine, Lacosamide, Levetiracetam, Lamotrigine, Phenobarbital, Valproic acid) and 2 metabolites (10,11-Dihydro-10-hydroxy-carbamazepine (DHCB) and carbamazepine-10,11-epoxide) in DBS and VAMS samples. The method was fully validated for linearity, selectivity, accuracy, precision, carryover, matrix effect, recovery and stability (15days at room temperature and 72h in autosampler). Moreover, the volume effect, volcano effect, and the hematocrit (Hct) effect were also assessed for DBS samples. All parameters showed satisfactory results, with a limit of quantification ranging from 0.5 to 10µg/mL, depending on the analyte. Some instability issues were detected in DBS samples for oxcarbazepine. However, the inclusion of oxcarbazepine’s metabolite DHCB overcomes this problem as it was stable under both conditions tested. Moreover, this is the first DBS or VAMS method reporting the inclusion of DHCB, which seems essential for the TDM of oxcarbazepine. The method was applied to 80 paired samples from patients under treatment with these drugs in order to study the suitability of the method for the detection of these compounds, and compare concentrations in paired VAMS, DBS, whole blood and plasma samples. Ratios between paired samples show a promising correlation between microsampling techniques and plasma concentrations.

Description

Bibliographic citation

María Cobo-Golpe, Lucía Paniagua-González, Elena Lendoiro, Miriam Blanco-Ces, Ángela López-Rabuñal, Javier Abella, Dolores Castro, Cristina Melcón, Patricia Fuentes, Iria Carballeira, Carlos García, Carmen Gómez, Manuel López-Rivadulla Lamas, Angelines Cruz, Ana de-Castro-Ríos, Development and application of an LC-MS/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS), Journal of Analytical Toxicology, 2025;, bkaf073, https://doi.org/10.1093/jat/bkaf073

Relation

Has part

Has version

Is based on

Is part of

Is referenced by

Is version of

Requires

Sponsors

This publication is part of the R&D&I project PID2021- 124286OB-I00, financed by MCIN/AEI/10.13039/501100011033/ and by “ERDF A way of making Europe.” Plan Nacional sobre Drogas, Ministerio de Sanidad, Gobierno de España, for her contract (grant EXP2022/008675, financed by European Union NextGenerationEU/PRTR).

Rights

© The Author(s) 2025. Published by Oxford University Press. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
Attribution 4.0 International