Agreement on Anterior Chamber Depth Measurement between Three Commercially Available Devices

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física Aplicadaes_ES
dc.contributor.authorNoya Padín, Verónica
dc.contributor.authorPena Verdeal, Hugo
dc.contributor.authorGarcía Queiruga, Jacobo
dc.contributor.authorSampedro-Mariño, Irene
dc.contributor.authorGiráldez Fernández, María Jesús
dc.contributor.authorYebra-Pimentel Vilar, Eva
dc.date.accessioned2024-04-18T11:44:54Z
dc.date.available2024-04-18T11:44:54Z
dc.date.issued2024-04-17
dc.description.abstractThe present study aimed to assess the agreement of three commercially available devices on the measurement of anterior chamber depth (ACD) with and without compensation by central corneal thickness measurement (CCT). Fifty eyes were included in an observational cross-sectional study. Participants underwent a single visit during which devices were used to obtain the inclusion/exclusion (ARK510A, Canon TX-10) and studied (VX-120, Lenstar LS900 and EchoScan US-800) parameters. Based on invasiveness, tests were always performed in the same order by one researcher (to avoid inter-observer variability) and only in the right eye (to avoid overstating the precision of estimates) in each participant. The keratometry, autorefraction, intraocular pressure and anterior chamber angle values were used as inclusion criteria, while the CCT and ACD values were used in the agreement analysis between devices. There was a general and a paired difference in ACD measurements between devices (Greenhouse–Geisser: p ≤ 0.001; Sidak: all p ≤ 0.001). No significant difference was found in ACD measurements compensated by CCT values between the devices (Greenhouse–Geisser: p = 0.200). Pairwise analysis showed a significant difference in VX-120 vs. Lenstar (Sidak: p = 0.021). The differences in ACD measurements compensated by CCT values between the devices were clinically acceptable. Consequently, using these instruments interchangeably in daily routines based on this correction is justified.es_ES
dc.description.peerreviewedSIes_ES
dc.identifier.citationNoya-Padin, V.; PenaVerdeal, H.; Garcia-Queiruga, J.; Sampedro-Mariño, I.; Giraldez, M.J.; Yebra-Pimentel, E. Agreement on Anterior Chamber Depth Measurement between Three Commercially Available Devices. Photonics 2024, 11, 377es_ES
dc.identifier.doi10.3390/photonics11040377
dc.identifier.issn2304-6732
dc.identifier.urihttp://hdl.handle.net/10347/33549
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rights© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/
dc.subjectAnterior chamber depthes_ES
dc.subjectOcular biometric agreementes_ES
dc.subjectVX-120multi-diagnostic platformes_ES
dc.subjectLenstar LS900es_ES
dc.subjectEchoScan US-800es_ES
dc.subject.classification220915 Optometríaes_ES
dc.titleAgreement on Anterior Chamber Depth Measurement between Three Commercially Available Deviceses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationa33f1b46-c5e2-417e-99e1-317d1e6e3ff6
relation.isAuthorOfPublication8743c628-62df-4f90-a166-4946245a6e1f
relation.isAuthorOfPublication69b318a3-627d-45b7-97fa-d28c31908892
relation.isAuthorOfPublication45eab007-782a-4666-aac6-8c7020f1c661
relation.isAuthorOfPublication.latestForDiscoverya33f1b46-c5e2-417e-99e1-317d1e6e3ff6

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
photonics-11-00377.pdf
Size:
896.33 KB
Format:
Adobe Portable Document Format
Description:

Collections