Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology
Loading...
Identifiers
Publication date
Advisors
Tutors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Hindawi
Abstract
Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy) contact lens (CL) wearers with another modality of CL wear, overnight orthokeratology (OK). Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ) was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A) concentration with High-Performance Liquid Chromatography (HPLC). Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (, ) was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (, Kruskal–Wallis test). Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group
Description
Keywords
Bibliographic citation
Nery García-Porta, Laura Rico-del-Viejo, Alba Martin-Gil, Gonzalo Carracedo, Jesus Pintor, and José Manuel González-Méijome, “Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology,” BioMed Research International, vol. 2016, Article ID 1242845, 9 pages, 2016. doi:10.1155/2016/1242845
Relation
Has part
Has version
Is based on
Is part of
Is referenced by
Is version of
Requires
Publisher version
http://dx.doi.org/10.1155/2016/1242845Sponsors
This work was partially supported by
the Xunta de Galicia by a predoctoral grant of the Plan I2C
2011–2015 and the Spanish SAF2013-44416-R and RETICS
RD12/0034/0003. It was also partially supported by Portuguese
Foundation for Science and Technology (FCT) in
the framework of projects PTDC/SAU-BEB/098391/2008 and
PTDC/SAU-BEB/098392/2008
Rights
Copyright © 2016 Nery García-Porta et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited