Lanthanide-based peptide biosensor to monitor CDK4/cyclin D kinase activity
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Centro de Investigación en Química Biolóxica e Materiais Moleculares | gl |
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Química Orgánica | gl |
| dc.contributor.author | González-Vera, Juan A. | |
| dc.contributor.author | Bouzada Reboredo, David | |
| dc.contributor.author | Bouclier, Céline | |
| dc.contributor.author | Vázquez Sentís, Marco Eugenio | |
| dc.contributor.author | Morris, May C. | |
| dc.date.accessioned | 2018-07-13T12:39:22Z | |
| dc.date.available | 2018-07-13T12:39:22Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | We describe a lanthanide biosensor that responds to CDK4 kinase activity in melanoma cell extracts through a significant and dose dependent increase in luminescence, thanks to sensitization of a DOTA[Tb3+] complex incorporated into a CDK4 substrate peptide by a unique tryptophan residue in an adjacent phosphoaminoacid binding moiety | gl |
| dc.description.peerreviewed | SI | gl |
| dc.description.sponsorship | This work was funded by the CNRS (Centre National de la Recherche Scientifique) and a Marie-Curie fellowship EC-FP7 Framework (PIEF-GA-2013-623151) supporting JAGV. CB was funded by the INCA (PRTK-2014). Financial support from the Spanish MINECO (CTQ2015-70698-R), the Xunta de Galicia (Centro singular de investigacio´n de Galicia accreditation 2016–2019), and the European Union (European Regional Development Fund – ERDF), are gratefully acknowledged | gl |
| dc.identifier.citation | González-Vera, J., Bouzada, D., Bouclier, C., Eugenio Vázquez, M., & Morris, M. (2017). Lanthanide-based peptide biosensor to monitor CDK4/cyclin D kinase activity. Chemical Communications, 53(45), 6109-6112. doi: 10.1039/c6cc09948c | gl |
| dc.identifier.doi | 10.1039/C6CC09948C | |
| dc.identifier.essn | 1364-548X | |
| dc.identifier.issn | 1359-7345 | |
| dc.identifier.uri | http://hdl.handle.net/10347/17023 | |
| dc.language.iso | eng | gl |
| dc.publisher | Royal Society of Chemistry | gl |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/CTQ2015-70698-R/ES/SISTEMAS SUPRAMOLECULARES PARA RECONOCIMIENTO BIOMOLECULAR: HELICATOS PEPTIDICOS Y RECEPTORES OLIGOMERICOS AUTOENSAMBLADOS | |
| dc.relation.publisherversion | https://doi.org/10.1039/C6CC09948C | gl |
| dc.rights | © The Royal Society of Chemistry 2017 | gl |
| dc.rights.accessRights | open access | gl |
| dc.title | Lanthanide-based peptide biosensor to monitor CDK4/cyclin D kinase activity | gl |
| dc.type | journal article | gl |
| dc.type.hasVersion | AM | gl |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 34f1e1e8-411b-4b42-a25c-253481d3abef | |
| relation.isAuthorOfPublication.latestForDiscovery | 34f1e1e8-411b-4b42-a25c-253481d3abef |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2017_chemcommun_morris_lanthanide_peptide.pdf
- Size:
- 624 KB
- Format:
- Adobe Portable Document Format
- Description: