Quantification of temporomandibular joint space in patients with juvenile idiopathic arthritis assessed by cone beam computerized tomography
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Electrónica e Computación | es_ES |
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Física Aplicada | es_ES |
| dc.contributor.area | Área de Enxeñaría e Arquitectura | |
| dc.contributor.author | Otero, María Florinda | |
| dc.contributor.author | Tahoces, Pablo G. | |
| dc.contributor.author | Mera, Antonio | |
| dc.contributor.author | Dalstra, Michel | |
| dc.contributor.author | Verna, Carlalberta | |
| dc.contributor.author | Pedersen, Thomas Klit | |
| dc.contributor.author | Herlin, Troels | |
| dc.contributor.author | Mira Pérez, Jorge | |
| dc.date.accessioned | 2023-11-13T11:01:30Z | |
| dc.date.available | 2023-11-13T11:01:30Z | |
| dc.date.issued | 2023-08-01 | |
| dc.description.abstract | Objective To describe a method to calculate the total intra-articular volume (inter-osseous space) of the temporomandibular joint (TMJ) determined by cone-beam computed tomography (CBCT). This could be used as a marker of tissue proliferation and different degrees of soft tissue hyperplasia in juvenile idiopathic arthritis (JIA) patients. Materials and Methods Axial single-slice CBCT images of cross-sections of the TMJs of 11 JIA patients and 11 controls were employed. From the top of the glenoid fossa, in the caudal direction, an average of 26 slices were defined in each joint (N = 44). The interosseous space was manually delimited from each slice by using dedicated software that includes a graphic interface. TMJ volumes were calculated by adding the areas measured in each slice. Two volumes were defined: Ve−i and Vi, where Ve−i is the inter-osseous space, volume defined by the borders of the fossa and Vi is the internal volume defined by the condyle. An intra-articular volume filling index (IF) was defined as Ve−i/Vi, which represents the filling of the space. Results The measured space of the intra-articular volume, corresponding to the intra-articular soft tissue and synovial fluid, was more than twice as large in the JIA group as in the control group. Conclusion The presented method, based on CBCT, is feasible for assessing inter-osseus joint volume of the TMJ and delimits a threshold of intra-articular changes related to intra-articular soft tissue proliferation, based on differences in volumes. Intra-articular soft tissue is found to be enlarged in JIA patients | es_ES |
| dc.description.peerreviewed | SI | es_ES |
| dc.identifier.citation | Orthod Craniofac Res. 2023;00:1-8 | es_ES |
| dc.identifier.doi | 10.1111/ocr.12702 | |
| dc.identifier.essn | 1601-6343 | |
| dc.identifier.issn | 1601-6335 | |
| dc.identifier.uri | http://hdl.handle.net/10347/31264 | |
| dc.journal.title | Orthodontics & Craniofacial Research | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Wiley | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1111/ocr.12702 | es_ES |
| dc.rights | © 2023 The Authors. Orthodontics & Craniofacial Research published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes | es_ES |
| dc.rights | Atribución-NoComercial 4.0 Internacional | |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | |
| dc.subject | Cone-beam computed tomography | es_ES |
| dc.subject | Imaging | es_ES |
| dc.subject | Inflammation | es_ES |
| dc.subject | Juvenile idiopathic arthritis | es_ES |
| dc.subject | TMJ | es_ES |
| dc.title | Quantification of temporomandibular joint space in patients with juvenile idiopathic arthritis assessed by cone beam computerized tomography | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 80f5b8b1-a702-4f35-967d-0d93cce9518a | |
| relation.isAuthorOfPublication.latestForDiscovery | 80f5b8b1-a702-4f35-967d-0d93cce9518a |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2023_ortcran_otero_quantification.pdf
- Size:
- 3.86 MB
- Format:
- Adobe Portable Document Format
- Description:
- Artigo de investigación