Automatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scanners
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Centro de Investigación en Tecnoloxías da Información | gl |
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Psiquiatría, Radioloxía e Saúde Pública | |
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Electrónica e Computación | |
| dc.contributor.area | Área de Enxeñaría e Arquitectura | |
| dc.contributor.author | Souto Bayarri, José Miguel | |
| dc.contributor.author | Suárez Cuenca, Jorge Juan | |
| dc.contributor.author | García Tahoces, Pablo | |
| dc.contributor.author | Revel, Marie-Pierre | |
| dc.contributor.author | Delhaye, Damien | |
| dc.contributor.author | Carreira Villamor, José Martín | |
| dc.contributor.author | Remy-Jardin, Martin | |
| dc.contributor.author | Remy, Jacque | |
| dc.date.accessioned | 2018-11-21T12:47:13Z | |
| dc.date.available | 2018-11-21T12:47:13Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | The purpose of this study was to evaluate the diagnostic performance of a computer-aided diagnosis (CAD) system, on the detection of pulmonary nodules in multidetector row computed tomography (MDCT) images, by using two different MDCT scanners. The computerized scheme was based on the iris filter. We have collected CT cases of patients with pulmonary nodules. We have included in the study one hundred and thirty-two calcified and noncalcified nodules, measuring 4-30 mm in diameter. CT examinations were performed by using two different equipments: a CT scanner (SOMATOM Emotion 6), and a dual-source computed tomography system (SOMATOM Definition) (Siemens Medical System, Forchheim, Germany), with the following parameters: collimation, 6x1.0mm (Emotion 6); and 64×0.6mm (Definition); 100-130 kV; 70-110 mAs. Data were reconstructed with a slice thickness of 1.25mm (Emotion 6) and 1mm (Definition). True positive cases were determined by an independent interpretation of the study by three experienced chest radiologists, the panel decision being used as the reference standard. Free-response Receiver Operating Characteristic curves, sensitivity and number of false-positive per scan, were calculated. Our CAD scheme, for the test set of the study, yielded a sensitivity of 80%, with an average of 5.2 FPs per examination. At an average false positive rate of 9 per scan, our CAD scheme achieved sensitivities of 94% for all nodules, 94.5% for solid, 80% for non-solid, 84% for spiculated, and 97% for non-spiculated nodules. These encouraging results suggest that our CAD system, advocated as a second reader, may help radiologists in the detection of lung nodules in MDCT | gl |
| dc.description.peerreviewed | SI | gl |
| dc.description.sponsorship | This work has been partially supported by the Xunta de Galicia (expte. nº PGIDIT06BTF20802PR), and by the FIS (expte. nº PI060058) and (expte. nº PI080072) | gl |
| dc.identifier.citation | BAYARRI, M., Suárez-Cuenca, J., Tahoces, P., Revel, M., Delhaye, D., & Carreira, J. et al. (2012). Automatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scanners. Journal Of Biomedical Graphics And Computing, 2(2). doi: 10.5430/jbgc.v2n2p55 | gl |
| dc.identifier.doi | 10.5430/jbgc.v2n2p55 | |
| dc.identifier.essn | 1925-4016 | |
| dc.identifier.issn | 1925-4008 | |
| dc.identifier.uri | http://hdl.handle.net/10347/17788 | |
| dc.language.iso | eng | gl |
| dc.publisher | Sciedu Press | gl |
| dc.relation.publisherversion | https://doi.org/10.5430/jbgc.v2n2p55 | gl |
| dc.rights | © 2012 Sciedu Press | gl |
| dc.rights.accessRights | open access | gl |
| dc.subject | Computer aided diagnosis | gl |
| dc.subject | Computer-aided diagnosis | gl |
| dc.subject | Multidetector row computed tomography | gl |
| dc.subject | Pulmonary nodule | gl |
| dc.subject | Automatic detection of pulmonary nodules | gl |
| dc.title | Automatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scanners | gl |
| dc.type | journal article | gl |
| dc.type.hasVersion | VoR | gl |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 64b61b32-0acf-4977-a258-56bb34b766f8 | |
| relation.isAuthorOfPublication.latestForDiscovery | 64b61b32-0acf-4977-a258-56bb34b766f8 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2012_sciedu_souto_automatic.pdf
- Size:
- 215.23 KB
- Format:
- Adobe Portable Document Format
- Description: