Automatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scanners

dc.contributor.affiliationUniversidade de Santiago de Compostela. Centro de Investigación en Tecnoloxías da Informacióngl
dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Psiquiatría, Radioloxía e Saúde Pública
dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Electrónica e Computación
dc.contributor.areaÁrea de Enxeñaría e Arquitectura
dc.contributor.authorSouto Bayarri, José Miguel
dc.contributor.authorSuárez Cuenca, Jorge Juan
dc.contributor.authorGarcía Tahoces, Pablo
dc.contributor.authorRevel, Marie-Pierre
dc.contributor.authorDelhaye, Damien
dc.contributor.authorCarreira Villamor, José Martín
dc.contributor.authorRemy-Jardin, Martin
dc.contributor.authorRemy, Jacque
dc.date.accessioned2018-11-21T12:47:13Z
dc.date.available2018-11-21T12:47:13Z
dc.date.issued2012
dc.description.abstractThe purpose of this study was to evaluate the diagnostic performance of a computer-aided diagnosis (CAD) system, on the detection of pulmonary nodules in multidetector row computed tomography (MDCT) images, by using two different MDCT scanners. The computerized scheme was based on the iris filter. We have collected CT cases of patients with pulmonary nodules. We have included in the study one hundred and thirty-two calcified and noncalcified nodules, measuring 4-30 mm in diameter. CT examinations were performed by using two different equipments: a CT scanner (SOMATOM Emotion 6), and a dual-source computed tomography system (SOMATOM Definition) (Siemens Medical System, Forchheim, Germany), with the following parameters: collimation, 6x1.0mm (Emotion 6); and 64×0.6mm (Definition); 100-130 kV; 70-110 mAs. Data were reconstructed with a slice thickness of 1.25mm (Emotion 6) and 1mm (Definition). True positive cases were determined by an independent interpretation of the study by three experienced chest radiologists, the panel decision being used as the reference standard. Free-response Receiver Operating Characteristic curves, sensitivity and number of false-positive per scan, were calculated. Our CAD scheme, for the test set of the study, yielded a sensitivity of 80%, with an average of 5.2 FPs per examination. At an average false positive rate of 9 per scan, our CAD scheme achieved sensitivities of 94% for all nodules, 94.5% for solid, 80% for non-solid, 84% for spiculated, and 97% for non-spiculated nodules. These encouraging results suggest that our CAD system, advocated as a second reader, may help radiologists in the detection of lung nodules in MDCTgl
dc.description.peerreviewedSIgl
dc.description.sponsorshipThis work has been partially supported by the Xunta de Galicia (expte. nº PGIDIT06BTF20802PR), and by the FIS (expte. nº PI060058) and (expte. nº PI080072)gl
dc.identifier.citationBAYARRI, M., Suárez-Cuenca, J., Tahoces, P., Revel, M., Delhaye, D., & Carreira, J. et al. (2012). Automatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scanners. Journal Of Biomedical Graphics And Computing, 2(2). doi: 10.5430/jbgc.v2n2p55gl
dc.identifier.doi10.5430/jbgc.v2n2p55
dc.identifier.essn1925-4016
dc.identifier.issn1925-4008
dc.identifier.urihttp://hdl.handle.net/10347/17788
dc.language.isoenggl
dc.publisherSciedu Pressgl
dc.relation.publisherversionhttps://doi.org/10.5430/jbgc.v2n2p55gl
dc.rights© 2012 Sciedu Pressgl
dc.rights.accessRightsopen accessgl
dc.subjectComputer aided diagnosisgl
dc.subjectComputer-aided diagnosisgl
dc.subjectMultidetector row computed tomographygl
dc.subjectPulmonary nodulegl
dc.subjectAutomatic detection of pulmonary nodulesgl
dc.titleAutomatic detection of pulmonary nodules: Evaluation of performance using two different MDCT scannersgl
dc.typejournal articlegl
dc.type.hasVersionVoRgl
dspace.entity.typePublication
relation.isAuthorOfPublication64b61b32-0acf-4977-a258-56bb34b766f8
relation.isAuthorOfPublication.latestForDiscovery64b61b32-0acf-4977-a258-56bb34b766f8

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2012_sciedu_souto_automatic.pdf
Size:
215.23 KB
Format:
Adobe Portable Document Format
Description: