Fitzhenry, KellyClifford, EoghanRowan, NeilVal del Río, Ángeles2021-08-122021-08-122021Journal of Water Process Engineering 2021, 41: 102070. https://doi.org/10.1016/j.jwpe.2021.1020702214-7144http://hdl.handle.net/10347/26802Pulsed UV (PUV) technology is accepted commercially for disinfection within the food packaging industry, but has yet to be deployed by the water/wastewater sector. This is partly due to a lack of robust, independently validated data for submerged or flow-through treatment applications. This study evaluated the efficacy of PUV for water disinfection under flow-through conditions. Bacterial pathogens of interest in the food and water/wastewater sector, namely Escherichia coli, Staphylococcus aureus and Listeria innocua (surrogate for L. monocytogenes) were used to investigate the potential for photoreactivation and/or dark repair post PUV flow-through disinfection. A continuous-flow low-pressure UV was also analysed under similar experimental conditions. Bacterial inactivation via flow-through PUV was dependant on energy output with E. coli exhibiting greatest sensitivity to PUV treatment (5.3 log 10 inactivation after treatment at 1539 mJ/cm 2 - output in UV range < 300 nm); L. innocua exhibited the highest PUV resistance (3.0 log 10 inactivation after treatment at 1539 mJ/cm 2 – output in UV range < 300 nm) under similar treatment conditions. Greater photoreactivation occurred at lower PUV outputs for both S. aureus and E. coli after flow-through PUV treatment. Thus exposure of treated bacteria to natural light, immediately post flow-through PUV treatment, should be avoided to minimise photoreactivation. The LPUV demonstrated inactivation of all bacteria below the limit of detection (1 CFU/mL) and inhibited the occurrence of photoreactivation. This study highlights the importance of considering bacterial repair potential and the need for further development of PUV technology for such applicationseng© 2021 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)Atribución 4.0 Internacionalhttp://creativecommons.org/licenses/by/4.0/Ultraviolet applicationsBacterial disinfectionWastewater treatmentCell injuryPulsed UVDisease mitigationBacterial inactivation, photoreactivation and dark repair post flow-through pulsed UV disinfectionjournal article10.1016/j.jwpe.2021.102070open access