Evolution of NH3 Concentrations in Weaner Pig Buildings Based on Setpoint Temperature

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Enxeñaría Agroforestalgl
dc.contributor.areaÁrea de Enxeñaría e Arquitectura
dc.contributor.authorFernández Rodríguez, María Dolores
dc.contributor.authorRodríguez Rodríguez, Manuel Ramiro
dc.contributor.authorLosada, Eugenio
dc.contributor.authorBesteiro, Roberto
dc.contributor.authorArango López, Tamara
dc.contributor.authorVelo Sabín, Ramón
dc.contributor.authorOrtega Martínez, Juan Antonio
dc.date.accessioned2020-04-28T11:35:24Z
dc.date.available2020-04-28T11:35:24Z
dc.date.issued2020
dc.description.abstractAmmonia (NH3) concentration has seldom been used for environmental control of weaner buildings despite its impact on environment, animal welfare, and workers’ health. This paper aims to determine the effects of setpoint temperature (ST) on the daily evolution of NH3 concentration in the animal-occupied zone. An experimental test was conducted on a conventional farm, with ST between 23 °C and 26 °C. NH3 concentrations in the animal-occupied zone were dependent on ST insofar as ST controlled the operation of the ventilation system, which effectively removed NH3 from the building. The highest NH3 concentrations occurred at night and the lowest concentrations occurred during the daytime. Data were fitted to a sinusoidal model using the least squares setting (LSS) and fast Fourier transform (FFT), which provided R2 values between 0.71 and 0.93. FFT provided a better fit than LSS, with root mean square errors (RMSEs) between 0.09 ppm for an ST of 23 °C and 0.55 ppm for an ST of 25 °C. A decrease in ST caused a delay in the wave and a decrease in wave amplitude. The proposed equations can be used for modeling NH3 concentrations and implemented in conventional controllers for real-time environmental control of livestock buildings to improve animal welfare and productivitygl
dc.description.peerreviewedSIgl
dc.description.sponsorshipThis research was funded by Xunta de Galicia, grant number GPC-ED431B 2018/012gl
dc.identifier.citationRodriguez, M.R.; Losada, E.; Besteiro, R.; Arango, T.; Velo, R.; Ortega, J.A.; Fernandez, M.D. Evolution of NH3 Concentrations in Weaner Pig Buildings Based on Setpoint Temperature. Agronomy 2020, 10, 107gl
dc.identifier.doi10.3390/agronomy10010107
dc.identifier.essn2073-4395
dc.identifier.urihttp://hdl.handle.net/10347/21850
dc.language.isoenggl
dc.publisherMDPIgl
dc.relation.publisherversionhttps://doi.org/10.3390/agronomy10010107gl
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/)gl
dc.rights.accessRightsopen accessgl
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectAmmonia daily variationgl
dc.subjectSinusoidal patterngl
dc.subjectEnvironmental controlgl
dc.subjectAnimal-occupied zonegl
dc.subjectFast Fourier transformgl
dc.titleEvolution of NH3 Concentrations in Weaner Pig Buildings Based on Setpoint Temperaturegl
dc.typejournal articlegl
dc.type.hasVersionVoRgl
dspace.entity.typePublication
relation.isAuthorOfPublicationc3fbefe7-a131-4e34-8b32-6bd2c23e6a30
relation.isAuthorOfPublication0a58a6a9-269c-4e98-9f30-db6edd086920
relation.isAuthorOfPublicationf5fdfa74-6168-44ba-883d-e34e5bfb2014
relation.isAuthorOfPublicationfc73abae-40e5-4189-bf25-d2f667792297
relation.isAuthorOfPublication.latestForDiscoveryc3fbefe7-a131-4e34-8b32-6bd2c23e6a30

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2020_agronomy_rodriguez_evolution.pdf
Size:
1.25 MB
Format:
Adobe Portable Document Format
Description: