Unveiling saturation effects from nuclear structure function measurements at the EIC

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física de Partículasgl
dc.contributor.authorMarquet, C.
dc.contributor.authorMoldes, Manoel R.
dc.contributor.authorZurita, María Pía
dc.date.accessioned2018-10-22T14:52:38Z
dc.date.available2018-10-22T14:52:38Z
dc.date.issued2017
dc.description.abstractWe analyze the possibility of extracting a clear signal of non-linear parton saturation effects from future measurements of nuclear structure functions at the Electron–Ion Collider (EIC), in the small-x region. Our approach consists in generating pseudodata for electron-gold collisions, using the running-coupling Balitsky–Kovchegov evolution equation, and in assessing the compatibility of these saturated pseudodata with existing sets of nuclear parton distribution functions (nPDFs), extrapolated if necessary. The level of disagreement between the two is quantified by applying a Bayesian reweighting technique. This allows to infer the parton distributions needed in order to describe the pseudodata, which we find quite different from the actual distributions, especially for sea quarks and gluons. This tension suggests that, should saturation effects impact the future nuclear structure function data as predicted, a successful refitting of the nPDFs may not be achievable, which would unambiguously signal the presence of non-linear effectsgl
dc.description.peerreviewedSIgl
dc.description.sponsorshipThis research was supported by the European Research Council grant HotLHC ERC-2011-StG-279579; Ministerio de Ciencia e Innovación of Spain under project FPA2014-58293-C2-1-P; Xunta de Galicia (Con-sellería de Educación) — the group is part of the Strategic Unit AGRUP2015/11. P.Z. was supported in part by the Office of Nu-clear Physics within the U.S. DOE Office of Science. M.R.M. was supported by Spanish INEM (SEPE)gl
dc.identifier.citationMarquet, C., Moldes, M., & Zurita, P. (2017). Unveiling saturation effects from nuclear structure function measurements at the EIC. Physics Letters B, 772, 607-614. doi: 10.1016/j.physletb.2017.07.035gl
dc.identifier.doi10.1016/j.physletb.2017.07.035
dc.identifier.issn0370-2693
dc.identifier.urihttp://hdl.handle.net/10347/17599
dc.language.isoenggl
dc.publisherElseviergl
dc.relation.publisherversionhttps://doi.org/10.1016/j.physletb.2017.07.035gl
dc.rights© 2017 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). Funded by SCOAP3gl
dc.rights.accessRightsopen accessgl
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleUnveiling saturation effects from nuclear structure function measurements at the EICgl
dc.typejournal articlegl
dc.type.hasVersionVoRgl
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017_PLB_Marquet_Unveiling.pdf
Size:
610.89 KB
Format:
Adobe Portable Document Format
Description: