Abstract

Sludge is one of the most problematic residues generated during wastewater treatment. Herein, we validate a single-step, sensitive procedure for the determination of a selection of 46 basic micro-pollutants, either used as pharmaceuticals or pesticides, in sludge from municipal sewage treatment plants (STPs), using liquid chromatography tandem mass spectrometry as determination technique. The proposed method permitted to achieve accurate recoveries (values from 70% to 120%, for samples spiked at different concentration levels) using solvent-based calibration standards. This feature, combined with limits of quantification lower than 5 ng g−1 (dry weight), allowed the rapid and sensitive quantification of target compounds in freeze-dried sludge samples. Out of 46 investigated pollutants, 33 species showed detection frequencies above 85% in a group of 48 sludge samples, obtained from 45 STPs located in the Northwest of Spain. The assessment of eco-toxicological risks associated to sludge disposal as fertilizer in agriculture and/or forestry, considering average concentrations found in sludge samples, highlighted eight pollutants (sertraline, venlafaxine, N-desethyl amiodarone, amiodarone, norsertraline, trazodone, amitriptyline and ketoconazole) representing an environmental hazard based on ratios between predicted soil levels and non-effect concentrations estimated using the equilibrium partition method

Description

Bibliographic citation

Chemosphere 335 (2023) 139094

Relation

Has part

Has version

Is based on

Is part of

Is referenced by

Is version of

Requires

Sponsors

Economic support from projects PGC2018-094613-B-I0 and ED431C2021/06 funded by the Ministry of Science and Innovation and Xunta de Galicia, both co-financed the EU FEDER program, is acknowledged. We thank Indrops laboratories, Aqualia, Espina & Delfin and Agilent Technologies for providing sludge samples and access to the LC-MS/MS instrumentation used in this research

Rights

© 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync- nd/4.0/)