Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Física Aplicada | |
| dc.contributor.author | Nores Palmás, Noelia | |
| dc.contributor.author | Noya Padín, Verónica | |
| dc.contributor.author | Yebra-Pimentel Vilar, Eva | |
| dc.contributor.author | Giráldez Fernández, María Jesús | |
| dc.contributor.author | Pena Verdeal, Hugo | |
| dc.date.accessioned | 2024-10-23T10:46:14Z | |
| dc.date.available | 2024-10-23T10:46:14Z | |
| dc.date.issued | 2024-10-18 | |
| dc.description.abstract | The study aimed to assess the agreement between OptoTab SERIES, alternating Cover Test, Modified Thorington test, and Von Graefe method in measuring heterophoria and accommodative convergence over accommodation (AC/A) ratio. In an initial step, heterophoria was assessed at both distance and near in a cohort of 76 healthy young volunteers using the previously described tests. Subsequently, to determine the AC/A ratio, near-vision measurements were repeated with +1.00 D and −1.00 D lenses. All tests were performed in a randomized order across participants under consistent conditions. Significant differences were found between the Modified Thorington test and all other tests at distance (Wilcoxon test, all p ≤ 0.001) and between Von Graefe and all other tests at near (Wilcoxon test, all p ≤ 0.005). Regarding the AC/A ratio, significant differences were observed between all methods in +1.00 D AC/A ratio, except for the Modified Thorington test vs. the alternating Cover Test (Wilcoxon test, p = 0.024). In the −1.00 D AC/A ratio, differences were observed between OptoTab POCKET and all the other tests (Wilcoxon test, all p ≤ 0.001). The results indicate that all methods are interchangeable except the Modified Thorington test at distance and Von Graefe at near. For the AC/A ratio, only the Modified Thorington test is interchangeable with the alternating Cover Test using +1.00 D lenses and all are interchangeable using −1.00 D lenses except OptoTab POCKET. | |
| dc.description.peerreviewed | SI | |
| dc.identifier.citation | Nores-Palmas N, Noya-Padin V, Yebra-Pimentel E, Giraldez MJ, Pena-Verdeal H. Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio. Vision. 2024; 8(4):62 | |
| dc.identifier.doi | 10.3390/vision8040062 | |
| dc.identifier.issn | 2411-5150 | |
| dc.identifier.uri | https://hdl.handle.net/10347/37540 | |
| dc.issue.number | 62 | |
| dc.journal.title | Vision | |
| dc.language.iso | eng | |
| dc.publisher | MDPI | |
| dc.relation.publisherversion | https://doi.org/10.3390/vision8040062 | |
| dc.rights | © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license | |
| dc.rights | Attribution 4.0 International | en |
| dc.rights.accessRights | open access | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Heterophoria | |
| dc.subject | AC/A ratio | |
| dc.subject | OptoTab SERIES | |
| dc.subject | Cover Test | |
| dc.subject | Modified Thorington test | |
| dc.subject | Von Graefe | |
| dc.title | Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 8(4) | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 45eab007-782a-4666-aac6-8c7020f1c661 | |
| relation.isAuthorOfPublication | 69b318a3-627d-45b7-97fa-d28c31908892 | |
| relation.isAuthorOfPublication | a33f1b46-c5e2-417e-99e1-317d1e6e3ff6 | |
| relation.isAuthorOfPublication.latestForDiscovery | a33f1b46-c5e2-417e-99e1-317d1e6e3ff6 |
Files
Original bundle
1 - 1 of 1