Inter-week variation of meibometry and tear break-up time in healthy subjects
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Física Aplicada | es_ES |
| dc.contributor.author | García Queiruga, Jacobo | |
| dc.contributor.author | Pena Verdeal, Hugo | |
| dc.contributor.author | Giráldez Fernández, María Jesús | |
| dc.contributor.author | García Resúa, Carlos | |
| dc.contributor.author | Yebra-Pimentel Vilar, Eva | |
| dc.date.accessioned | 2024-01-31T08:57:47Z | |
| dc.date.available | 2024-01-31T08:57:47Z | |
| dc.date.issued | 2021-08 | |
| dc.description.abstract | Clinical relevance: Variation with time in the tear film parameters should be considered by the clinician since measurements are made can influence proper diagnosis. Background: A hallmark of dry eye is an unstable tear film associated with variability in objective daily measures. The purpose of the present study was to evaluate the inter-week repeatability of meibometry, break-up time (BUT) and maximum blink interval (MBI) in healthy subjects. Methods: Forty healthy subjects were recruited for the study. Meibometry, BUT and MBI were performed twice in two sessions, one-week apart. Meibum from the lower eyelid was collected and quantified with the Meibometer MB550. Five meibomian curves were generated by tape and each peak value was averaged as a mean value per session. BUT and MBI were determined three times after fluorescein instillation and recorded by a DV-3 camera attached to the slit lamp. BUT and MBI videos were analysed by a second masked observer. Both BUT and MBI values were calculated by averaging the two most similar measurements of the three evaluated. Results: No statistical difference between inter-week sessions was obtained for the meibometry (p > 0.340; Wilcoxon test), BUT (p > 0.326; Wilcoxon test) and MBI values (p ≥ 0.248; Wilcoxon test). Inter-week differences were low for BUT and MBI when time intervals were no longer than 15 seconds (both p ≥ 0.586; Wilcoxon test). A correlation between BUT and MBI was found (r ≥ 0.668, p < 0.001; Spearman Rho), while no statistical correlation was obtained between meibometry results and BUT or MBI (all p ≥ 0.194; Spearman Rho). Conclusion: Meibum secretion and the tear film stability present good intersession repeatability, and are stable along with sessions in healthy patients. | es_ES |
| dc.description.peerreviewed | SI | es_ES |
| dc.description.sponsorship | This study was funded by the Spanish Ministry of Science and Education and the Institute of Health Carlos III (ISCIII) through research project [PI10/01098]. | es_ES |
| dc.identifier.citation | Jacobo Garcia-Queiruga, Hugo Pena-Verdeal, Maria Jesus Giraldez, Carlos Garcia-Resua & Eva Yebra-Pimentel (2021) Inter-week variation of meibometry and tear break-up time in healthy subjects, Clinical and Experimental Optometry, 104:6, 691-697, DOI: 10.1080/08164622.2021.1878815 | es_ES |
| dc.identifier.doi | 10.1080/08164622.2021.1878815 | |
| dc.identifier.essn | 1444-0938 | |
| dc.identifier.issn | 0816-4622 | |
| dc.identifier.uri | http://hdl.handle.net/10347/32138 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Taylor and Francis | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1080/08164622.2021.1878815 | es_ES |
| dc.rights | CC BY-NC-ND | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.subject | Inter-week variation | es_ES |
| dc.subject | Meibometry | es_ES |
| dc.subject | Meibum | es_ES |
| dc.subject | Repeatability | es_ES |
| dc.subject | Tear break-up time | es_ES |
| dc.title | Inter-week variation of meibometry and tear break-up time in healthy subjects | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | AM | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 8743c628-62df-4f90-a166-4946245a6e1f | |
| relation.isAuthorOfPublication | a33f1b46-c5e2-417e-99e1-317d1e6e3ff6 | |
| relation.isAuthorOfPublication | 69b318a3-627d-45b7-97fa-d28c31908892 | |
| relation.isAuthorOfPublication | c3d974d9-f3f1-4d54-b5d1-539f311d9af0 | |
| relation.isAuthorOfPublication | 45eab007-782a-4666-aac6-8c7020f1c661 | |
| relation.isAuthorOfPublication.latestForDiscovery | a33f1b46-c5e2-417e-99e1-317d1e6e3ff6 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- S2_2021_Repos_Inter week variation of meibometry and tear break up time.txt.pdf
- Size:
- 194.68 KB
- Format:
- Adobe Portable Document Format
- Description: