Inter-week variation of meibometry and tear break-up time in healthy subjects

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física Aplicadaes_ES
dc.contributor.authorGarcía Queiruga, Jacobo
dc.contributor.authorPena Verdeal, Hugo
dc.contributor.authorGiráldez Fernández, María Jesús
dc.contributor.authorGarcía Resúa, Carlos
dc.contributor.authorYebra-Pimentel Vilar, Eva
dc.date.accessioned2024-01-31T08:57:47Z
dc.date.available2024-01-31T08:57:47Z
dc.date.issued2021-08
dc.description.abstractClinical relevance: Variation with time in the tear film parameters should be considered by the clinician since measurements are made can influence proper diagnosis. Background: A hallmark of dry eye is an unstable tear film associated with variability in objective daily measures. The purpose of the present study was to evaluate the inter-week repeatability of meibometry, break-up time (BUT) and maximum blink interval (MBI) in healthy subjects. Methods: Forty healthy subjects were recruited for the study. Meibometry, BUT and MBI were performed twice in two sessions, one-week apart. Meibum from the lower eyelid was collected and quantified with the Meibometer MB550. Five meibomian curves were generated by tape and each peak value was averaged as a mean value per session. BUT and MBI were determined three times after fluorescein instillation and recorded by a DV-3 camera attached to the slit lamp. BUT and MBI videos were analysed by a second masked observer. Both BUT and MBI values were calculated by averaging the two most similar measurements of the three evaluated. Results: No statistical difference between inter-week sessions was obtained for the meibometry (p > 0.340; Wilcoxon test), BUT (p > 0.326; Wilcoxon test) and MBI values (p ≥ 0.248; Wilcoxon test). Inter-week differences were low for BUT and MBI when time intervals were no longer than 15 seconds (both p ≥ 0.586; Wilcoxon test). A correlation between BUT and MBI was found (r ≥ 0.668, p < 0.001; Spearman Rho), while no statistical correlation was obtained between meibometry results and BUT or MBI (all p ≥ 0.194; Spearman Rho). Conclusion: Meibum secretion and the tear film stability present good intersession repeatability, and are stable along with sessions in healthy patients.es_ES
dc.description.peerreviewedSIes_ES
dc.description.sponsorshipThis study was funded by the Spanish Ministry of Science and Education and the Institute of Health Carlos III (ISCIII) through research project [PI10/01098].es_ES
dc.identifier.citationJacobo Garcia-Queiruga, Hugo Pena-Verdeal, Maria Jesus Giraldez, Carlos Garcia-Resua & Eva Yebra-Pimentel (2021) Inter-week variation of meibometry and tear break-up time in healthy subjects, Clinical and Experimental Optometry, 104:6, 691-697, DOI: 10.1080/08164622.2021.1878815es_ES
dc.identifier.doi10.1080/08164622.2021.1878815
dc.identifier.essn1444-0938
dc.identifier.issn0816-4622
dc.identifier.urihttp://hdl.handle.net/10347/32138
dc.language.isoenges_ES
dc.publisherTaylor and Francises_ES
dc.relation.publisherversionhttps://doi.org/10.1080/08164622.2021.1878815es_ES
dc.rightsCC BY-NC-NDes_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectInter-week variationes_ES
dc.subjectMeibometryes_ES
dc.subjectMeibumes_ES
dc.subjectRepeatabilityes_ES
dc.subjectTear break-up timees_ES
dc.titleInter-week variation of meibometry and tear break-up time in healthy subjectses_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication8743c628-62df-4f90-a166-4946245a6e1f
relation.isAuthorOfPublicationa33f1b46-c5e2-417e-99e1-317d1e6e3ff6
relation.isAuthorOfPublication69b318a3-627d-45b7-97fa-d28c31908892
relation.isAuthorOfPublicationc3d974d9-f3f1-4d54-b5d1-539f311d9af0
relation.isAuthorOfPublication45eab007-782a-4666-aac6-8c7020f1c661
relation.isAuthorOfPublication.latestForDiscoverya33f1b46-c5e2-417e-99e1-317d1e6e3ff6

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
S2_2021_Repos_Inter week variation of meibometry and tear break up time.txt.pdf
Size:
194.68 KB
Format:
Adobe Portable Document Format
Description:

Collections