Root temperature and energy consumption at different cable depths in electrically heated substrates

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Enxeñaría Agroforestalgl
dc.contributor.areaÁrea de Enxeñaría e Arquitectura
dc.contributor.authorFernández Rodríguez, María Dolores
dc.contributor.authorRodríguez Rodríguez, Manuel Ramiro
dc.contributor.authorLópez Pidre, Rafael
dc.contributor.authorTeijeiro Rodríguez, María Teresa
dc.date.accessioned2020-04-27T15:46:50Z
dc.date.available2020-04-27T15:46:50Z
dc.date.issued2011
dc.description.abstractA finite element method-based model of a substrate heated by an electric heating cable buried in a thermal isolated container was experimentally validated with root mean square error values of root zone temperature ranging 0.25 to 0.62 ºC. The two-dimensional transient model allowed variations in the physical properties of the substrate with temperature, water content and depth. The operation of nine configurations of a heating cable buried in sand at different depths (50 to 450 mm, at 50 mm intervals) at 200 mm spacing was simulated and assessed. The validated model was used to perform 24-h simulations applying boundary conditions, and substrate moisture content was experimentally obtained at a mean substrate surface temperature of 13.98 ºC. Such simulations reproduced the operation of the heating system by setting a reference temperature of 20 ºC at the control point in the root zone. Burying the heating cable in the surface layers of the substrate caused large temperature gradients and high heat losses through the substrate surface. Accordingly, average temperature in the root zone increased with heating cable depth, up to the 200 mm depth. For greater depths, temperature in the root zone was constant. The ON/OFF control was most effective with the heating cable buried in the root zone and at control point temperatures of 20 ± 1 ºC. Burying the heating cable in the surface layers required higher energy consumption, up to 28 % at 50 mm. The most efficient heating cable depth was 350 mm, with a daily energy consumption of 6750 kJ m-2.gl
dc.description.peerreviewedSIgl
dc.identifier.citationFernandez, María Dolores, Rodriguez, Manuel Ramiro, Pidre, Rafael López, & Teijeiro, Teresa. (2011). Root temperature and energy consumption at different cable depths in electrically heated substrates. "Scientia Agricola", 68(5), 511-517gl
dc.identifier.doi10.1590/S0103-90162011000500001
dc.identifier.essn1678-992X
dc.identifier.issn0103-9016
dc.identifier.urihttp://hdl.handle.net/10347/21815
dc.language.isoenggl
dc.publisherUniversidade de São Paulogl
dc.relation.publisherversionhttps://doi.org/10.1590/S0103-90162011000500001gl
dc.rightsCopyright (c) 2011 Scientia Agricola. This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International Licensegl
dc.rights.accessRightsopen accessgl
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/
dc.subjectFEM modelgl
dc.subjectHeat consumptiongl
dc.subjectHeating systemsgl
dc.subjectSoil heatinggl
dc.titleRoot temperature and energy consumption at different cable depths in electrically heated substratesgl
dc.typejournal articlegl
dc.type.hasVersionVoRgl
dspace.entity.typePublication
relation.isAuthorOfPublicationc3fbefe7-a131-4e34-8b32-6bd2c23e6a30
relation.isAuthorOfPublication0a58a6a9-269c-4e98-9f30-db6edd086920
relation.isAuthorOfPublication41bfe587-35b0-4e13-9d99-c86bd65cd7b4
relation.isAuthorOfPublication.latestForDiscoveryc3fbefe7-a131-4e34-8b32-6bd2c23e6a30

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2011_sciagric_fernandez_root_temperature.pdf
Size:
835.63 KB
Format:
Adobe Portable Document Format
Description: