Volumetric Absorptive Microsampling (VAMS) for assayingimmunosuppressants from venous whole blood by LC–MS/MS using anovel atmospheric pressure ionization probe (UniSprayTM)

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Ciencias Forenses, Anatomía Patolóxica, Xinecoloxía e Obstetricia, e Pediatría
dc.contributor.authorPaniagua-González, Lucía
dc.contributor.authorDíaz-Louzao, Carla
dc.contributor.authorLendoiro Belío, Elena
dc.contributor.authorOtero-Antón, Esteban
dc.contributor.authorCadarso Suárez, Carmen María
dc.contributor.authorLópez-Rivadulla Lamas, Manuel
dc.contributor.authorCruz Landeira, Angelines
dc.contributor.authorCastro Ríos, Ana de
dc.date.accessioned2025-01-16T15:51:36Z
dc.date.available2025-01-16T15:51:36Z
dc.date.issued2020
dc.description.abstractTherapeutic drug monitoring (TDM) of immunosuppressants (IMS) is crucial to prevent rejection or toxicity after solid organ transplantation. Microsampling techniques (sampling <50 μL of blood) can be a good alternative to conventional venous sampling for TDM, due to their numerous advantages, including its easy and low-invasive sampling, enabling self-collection, and cost-saving shipment and storage. Furthermore, volumetric absorptive microsampling (VAMS) enables the collection of precise and accurate blood volumes, overcoming the hematocrit (Hct) effect related to dried blood spots, while offering the same benefits. In this work, an LC-MS/MS method for the determination of the 5 most common IMS (mycophenolic acid -MPA-, tacrolimus -TAC-, sirolimus -SIR-, everolimus -EVE- and cyclosporin A -CsA-) in venous blood collected with Mitra™ VAMS devices was developed and validated, employing a novel LC-MS/MS interface, Unispray™. The method was fully validated including linearity, limits of detection (LOD) and quantification (LLOQ), accuracy, precision, selectivity, carry-over, matrix effect, recovery, impact of Hct on recovery and autosampler and short-/long-term stability, satisfying acceptance criteria in all cases. LLOQs were 0.5 ng/mL for TAC, SIR and EVE, 20 ng/mL for CsA and 75 ng/mL for MPA. No impact of the Hct (range: 0.2 to 0.62 L/L) on recovery was found for any analyte. All compounds were stable in VAMS for at least 8 months at -20 °C. In addition, as part of the VAMS analytical method validation, we performed for the first time a broad statistical study to compare liquid venous blood concentrations from patients under TAC (n = 53) and MPA (n = 20) treatment to those observed when the same specimens were absorbed into VAMS. Our results showed that venous blood VAMS concentrations were correlated to those found in the original liquid venous blood, proving that the VAMS material itself will not bias blood drug concentrations. Therefore, the present method could be applied to evaluate possible correlations between venous blood and capillary blood collected with VAMS.
dc.description.peerreviewedSI
dc.identifier.citationPaniagua-González, L., Díaz-Louzao, C., Lendoiro, E., Otero-Antón, E., Cadarso-Suárez, C., López-Rivadulla, M., Cruz, A., & de-Castro-Ríos, A. (2020). Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS/MS using a novel atmospheric pressure ionization probe (UniSpray™). Journal of pharmaceutical and biomedical analysis, 189, 113422. https://doi.org/10.1016/j.jpba.2020.113422
dc.identifier.doi10.1016/j.jpba.2020.113422
dc.identifier.issn1873-264X
dc.identifier.urihttps://hdl.handle.net/10347/38627
dc.journal.titleJournal of pharmaceutical and biomedical analysis
dc.language.isoeng
dc.page.initial113422
dc.publisherElsevier
dc.rights.accessRightsopen access
dc.subjectImmunosuppressants
dc.subjectTacrolimus
dc.subjectVolumetric Absorptive Microsampling
dc.subjectUniSpray
dc.subjectLC-MS/MS
dc.subjectTherapeutic Drug Monitoring
dc.titleVolumetric Absorptive Microsampling (VAMS) for assayingimmunosuppressants from venous whole blood by LC–MS/MS using anovel atmospheric pressure ionization probe (UniSprayTM)
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number189
dspace.entity.typePublication
relation.isAuthorOfPublicationb19c766c-2fe8-4d0f-89c6-40b73a1ab3b3
relation.isAuthorOfPublication75edf723-9599-41be-b0dd-e365144993e0
relation.isAuthorOfPublicationbbe1bab3-19e8-4a4a-83f5-26549ecf0557
relation.isAuthorOfPublicationdf83fccc-7b97-459a-850b-f6783ab59440
relation.isAuthorOfPublicationc972b8db-3a4f-4de0-8379-2731ab2136fd
relation.isAuthorOfPublication.latestForDiscoveryb19c766c-2fe8-4d0f-89c6-40b73a1ab3b3

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
VAMS-version aceptada.pdf
Size:
985.98 KB
Format: