UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física Aplicada
dc.contributor.authorBaluja, Aurora
dc.contributor.authorArines Piferrer, Justo
dc.contributor.authorVilanova, Ramón
dc.contributor.authorCortiñas, Julio
dc.contributor.authorBao Varela, María del Carmen
dc.contributor.authorFlores Arias, María Teresa
dc.date.accessioned2025-12-11T08:57:10Z
dc.date.available2025-12-11T08:57:10Z
dc.date.issued2020-08-14
dc.description.abstractThe SARS-CoV-2 pandemic has led to a global decrease in personal protective equipment (PPE), especially filtering facepiece respirators (FFRs). Ultraviolet-C wavelength is a promising way of decontamination, however adequate dosimetry is needed to ensure balance between over and underexposed areas and provide reliable results. Our study demonstrates that UVGI light irradiance varies significantly on different respirator angles and propose a method to decontaminate several masks at once ensuring appropriate dosage in shaded zones. An UVGI irradiator was built with internal dimensions of 69.5 x55x33 cm with three 15 W UV lamps. Inside, a grating of 58x41x15 cm was placed to hold the masks. Two different flat fold respirator models were used to assess irradiance, four of model Aura 9322 3 M of dimensions 17 x9x4 cm (tri-fold), and two of model SAFE 231FFP3NR (bi-fold) with dimensions 17 x6 x5 cm. An STN-SilverNova spectrometer was employed to verify wavelength spectrum and surface irradiance. A simulation was performed to find the irradiance pattern inside the box and the six masks placed inside. These simulations were carried out using the software DIALUX EVO 8.2. The data obtained reveal that the irradiance received inside the manufactured UVGI-irradiator depends not only on the distance between the lamps’ plane and the base of the respirators but also on the orientation and shape of the masks. This point becomes relevant to assure that all the respirators inside the chamber receive the correct dosage. Irradiance over FFR surfaces depend on several factors such as distance and angle of incidence of the light source. Careful irradiance measurement and simulation can ensure reliable dosage in the whole mask surface, balancing overexposure. Closed box systems might provide a more reliable, reproducible UVGI dosage than open settings.
dc.description.peerreviewedSI
dc.identifier.citationBaluja, A., Arines, J., Vilanova, R., Cortiñas, J., Bao-Varela, C., & Flores-Arias, M. T. (2020). UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety. Journal of Occupational and Environmental Hygiene, 17(9), 390–397. https://doi.org/10.1080/15459624.2020.1786576
dc.identifier.doi10.1080/15459624.2020.1786576
dc.identifier.essn1545-9632
dc.identifier.issn1545-9624
dc.identifier.urihttps://hdl.handle.net/10347/44395
dc.issue.number9
dc.journal.titleJournal of Occupational and Environmental Hygiene
dc.language.isoeng
dc.page.final397
dc.page.initial390
dc.publisherTaylor & Francis
dc.relation.projectIDinfo:eu-repo/grantAgreement/Axencia Galega de Innovación//ED431B2017%2F64
dc.relation.projectIDinfo:eu-repo/grantAgreement/Axencia Galega de Innovación//ED431E2018%2F08
dc.relation.publisherversionhttps://doi.org/10.1080/15459624.2020.1786576
dc.rightsThis is an Accepted Manuscript of an article published by Taylor & Francis in Journal of Occupational and Environmental Hygiene on14/08/2020, available at: https://doi.org/10.1080/15459624.2020.1786576
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCoronavirus
dc.subjectDosimetry
dc.subjectIrradiance
dc.subjectRespirator
dc.subjectUltraviolet
dc.titleUV light dosage distribution over irregular respirator surfaces. Methods and implications for safety
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number17
dspace.entity.typePublication
relation.isAuthorOfPublicationccfe3578-e3e8-454f-b21c-f35ff32f2835
relation.isAuthorOfPublication1f8163b4-1d5a-48bf-9acd-67404d7e9266
relation.isAuthorOfPublicationbdc8b111-e134-4989-974a-683df95c2a51
relation.isAuthorOfPublication.latestForDiscoveryccfe3578-e3e8-454f-b21c-f35ff32f2835

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Proof_print_UOEH_A_1786576.pdf
Size:
1.82 MB
Format:
Adobe Portable Document Format

Collections