Absolute Radiometric Calibration of TESS-W and SQM Night Sky Brightness Sensors
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Física Aplicada | gl |
| dc.contributor.author | Bará Viñas, Salvador | |
| dc.contributor.author | Tapia, Carlos E. | |
| dc.contributor.author | Zamorano, Jaime | |
| dc.date.accessioned | 2020-04-13T22:35:15Z | |
| dc.date.available | 2020-04-13T22:35:15Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | We develop a general optical model and describe the absolute radiometric calibration of the readings provided by two widely-used night sky brightness sensors based on irradiance-to-frequency conversion. The calibration involves the precise determination of the overall spectral sensitivity of the devices and also the constant G relating the output frequency of the light-to-frequency converter chip to the actual band-weighted and field-of-view averaged spectral radiance incident on the detector (brightness). From these parameters, we show how to define a rigorous astronomical absolute photometric system in which the sensor measurements can be reported in units of magnitudes per square arcsecond with precise physical meaning. | gl |
| dc.description.peerreviewed | SI | gl |
| dc.identifier.citation | Bará, S.; Tapia, C.E.; Zamorano, J. Absolute Radiometric Calibration of TESS-W and SQM Night Sky Brightness Sensors. Sensors 2019, 19, 1336 | gl |
| dc.identifier.doi | 10.3390/s19061336 | |
| dc.identifier.essn | 1424-8220 | |
| dc.identifier.uri | http://hdl.handle.net/10347/21346 | |
| dc.language.iso | eng | gl |
| dc.publisher | MDPI | gl |
| dc.relation.publisherversion | https://doi.org/10.3390/s19061336 | gl |
| dc.rights | © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/) | gl |
| dc.rights.accessRights | open access | gl |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Night sky brightness | gl |
| dc.subject | Radiance | gl |
| dc.subject | Astronomical magnitudes | gl |
| dc.subject | Light pollution | gl |
| dc.title | Absolute Radiometric Calibration of TESS-W and SQM Night Sky Brightness Sensors | gl |
| dc.type | journal article | gl |
| dc.type.hasVersion | VoR | gl |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 27c828d1-8c90-498c-a22e-4d5faf444576 | |
| relation.isAuthorOfPublication.latestForDiscovery | 27c828d1-8c90-498c-a22e-4d5faf444576 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2019_sensors_bara_radiometric_calibration.pdf
- Size:
- 1.05 MB
- Format:
- Adobe Portable Document Format
- Description: