Matrix solid-phase dispersion followed by liquid chromatographytandem mass spectrometry for the determination of selectiveciclooxygenase-2 inhibitors in sewage sludge samples

Research Projects

Organizational Units

Journal Issue

Abstract

A straightforward single-step extraction method based on matrix solid-phase dispersion (MSPD), followed by high-performance liquid chromatography with hybrid quadrupole time of flight mass spectrometry (LC–QTOF-MS), was developed and optimized to determine five non-steroidal anti-inflammatory drugs (Valdecoxib, Etoricoxib, Parecoxib, Celecoxib and 2,5-Dimethylcelecoxib) in sewage sludge samples. The influence of different operational parameters on the extraction efficiency a well as in the matrix effects of the produced extracts was evaluated in detail. Under final working conditions, freeze dried samples (0.2 g) were first soaked with 100 μL of aqueous potassium hydroxide solution (60%, w/v), mixed with 1 g of anhydrous sodium sulfate and dispersed with 1 g of Florisil. This blend was transferred to the top of a polypropylene column cartridge containing 3 g of silica. Analytes were recovered using 15 mL of hexane/acetone (1:2, v/v) mixture. The extracts were concentrated by evaporation and reconstituted with 1 mL of methanol/water (1:1, v/v), filtered and injected in the LC system. Quantification limits from 0.005 and 0.05 ng g−1 and absolute recoveries between 86 and 105% were achieved. Results indicated the presence of two of the targeted COXIBs in real samples of sewage sludge, the highest average concentration (22 ng g−1) corresponding to celecoxib. Moreover, the screening capabilities of the LC–QTOF-MS system demonstrated that the developed MSPD extraction procedure might be useful for the selective extraction of some other pharmaceuticals (e.g. amiodarone and their metabolite N-desethylamiodarone, miconazole, clotrimazole and ketoprofen) from sludge samples

Description

Bibliographic citation

Triñanes, S., Casais, M., Mejuto, M., & Cela, R. (2016). Matrix solid-phase dispersion followed by liquid chromatography tandem mass spectrometry for the determination of selective ciclooxygenase-2 inhibitors in sewage sludge samples. Journal Of Chromatography A, 1462, 35-43. doi: 10.1016/j.chroma.2016.07.044

Relation

Has part

Has version

Is based on

Is part of

Is referenced by

Is version of

Requires

Sponsors

This study has been supported by the Spanish Government and E.U. FEDER funds (project CTQ2015-68660-P) and Xunta de Galicia (GRC2013/020)

Rights

Attribution-NonCommercial-NoDerivatives 4.0 Internacional