Use of a cubic phase plate as solution for moderate astigmatism : preliminary study
Loading...
Identifiers
ISSN: 2171-8814
E-ISSN: 0030-3917
Publication date
Advisors
Tutors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Sociedad Española de Óptica
Abstract
This work analyzes the use of a single cubic phasemask as a solution to moderate astigmatism of different orientationsand magnitudes. The experimental results with artificial eye show that a cubic phasemask of the 7.07 µm-(Z33-Z3-3) @ 5mm pupillary diameter, can be a solution to the astigmatism up to 3D with different orientations. The logMAR visual acuity obtained for all orientations is close to 0.05 for pupil sizes of 3mm, 5 mm, 7 mm. These results are a good starting point for the development of contact lenses or intraocular lenses that do not require stabilization systems increasing tolerance to errors in the correction of the astigmatism.
Description
Bibliographic citation
Almaguer, C., Arines, J. (2017). Use of a cubic phase plate as solution for moderate astigmatism : preliminary study. "Optica Pura y Aplicada", vol. 5, n. 2, 155-163
Relation
Has part
Has version
Is based on
Is part of
Is referenced by
Is version of
Requires
Publisher version
http:/doi.org/10.7149/OPA.50.2.49014Sponsors
Este trabajo ha sido financiado por el Ministerio de Economía y Competitividad recursos FIS2013-46188-P y FIS2016-77319-C2-1-R
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International