Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors

dc.contributor.authorGuardiola, Consuelo
dc.contributor.authorBachiller Perea, Diana
dc.contributor.authorPrieto Pena, Juan
dc.contributor.authorJiménez-Ramos, María del Carmen
dc.contributor.authorGarcía López, Javier
dc.contributor.authorEsnault, C.
dc.contributor.authorFleta, Celeste
dc.contributor.authorQuirion, David
dc.contributor.authorGómez Rodríguez, Faustino
dc.date.accessioned2024-01-30T08:58:41Z
dc.date.available2024-01-30T08:58:41Z
dc.date.issued2021-06
dc.description.abstractIn this work we show the first microdosimetry measurements on a low energy proton beam with therapeutic-equivalent fluence rates by using the second generation of 3D-cylindrical microdetectors. The sensors belong to an improved version of a novel silicon-based 3D-microdetector design with electrodes etched inside silicon, which were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. A new microtechnology has been employed using quasi-toroid electrodes of 25 μm diameter and a depth of 20 μm within the silicon bulk, resulting in a well-defined cylindrical radiation sensitive volume. These detectors were tested at the 18 MeV proton beamline of the cyclotron at the National Accelerator Centre (CNA, Spain). They were assembled into an in-house low-noise readout electronics to assess their performance at a therapeutic-equivalent fluence rate. Microdosimetry spectra of lineal energy were recorded at several proton energies starting from 18 MeV by adding 50 μm thick tungsten foils gradually at the exit-window of the cyclotron external beamline, which corresponds to different depths along the Bragg curve. The experimental y¯F values in silicon cover from (5.7 ± 0.9) to (8.5 ± 0.4) keV μm-1 in the entrance to (27.4 ± 2.3) keV μm-1 in the distal edge. Pulse height energy spectra were crosschecked with Monte Carlo simulations and an excellent agreement was obtained. This work demonstrates the capability of the second generation 3D-microdetectors to assess accurate microdosimetric distributions at fluence rates as high as those used in clinical centers in proton therapy.es_ES
dc.description.peerreviewedSIes_ES
dc.description.sponsorshipC Guardiola thanks funding from the European Union’s Horizon research and innovation program under the Marie Sklodowska-Curie grant agreement No. 745109. D Bachiller-Perea and C Guardiola thanks funding from the CNRS-Momentum fellow. This project has been also supported by the H2020 project AIDA-2020, under Grant Agreement no. 654168. M C Jiménez-Ramos acknowledges support from the Spanish project RTI2018- 098117-B-C21 funded by the Ministry of Science, Innovation and Universities. This work made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. C Guardiola gratefully acknowledges the computational access from the CNRS/IN2P3 Computing Center(Lyon, France) for performing the Monte Carlo simulations.es_ES
dc.identifier.citationPhysics in Medicine and Biology Volume 66, Issue 117 June 2021 Article number 114001es_ES
dc.identifier.doi10.1088/1361-6560/abf811
dc.identifier.issn0031-9155
dc.identifier.urihttp://hdl.handle.net/10347/32068
dc.language.isoenges_ES
dc.publisherInstitute of Physics Publishinges_ES
dc.relation.projectIDEuropean Union’s Horizon research and innovation program Marie Sklodowska-Curie 745109es_ES
dc.relation.publisherversionhttps://doi.org/10.1088/1361-6560/abf811es_ES
dc.rightsOPEN ACCESS. CC BY 4.0 DEED Atribución 4.0 Internacional © 2021 Institute of Physics and Engineering in Medicinees_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.es
dc.subjectMicrodosimetryes_ES
dc.subjectProton Therapyes_ES
dc.subjectSilicon 3D microdetectorses_ES
dc.subject.classificationInvestigaciónes_ES
dc.titleMicrodosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectorses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationa4ac4015-c1fc-4a70-8268-a1ce2c060bbc
relation.isAuthorOfPublication.latestForDiscoverya4ac4015-c1fc-4a70-8268-a1ce2c060bbc

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Guardiola_2021_Phys._Med._Biol._66_114001.pdf
Size:
1.53 MB
Format:
Adobe Portable Document Format
Description: