Accuracy of refractive index spectroscopy by broadband interferometry

Research Projects

Organizational Units

Journal Issue

Abstract

Uncertainties of refractive and group index in dispersion measurement by spectrally resolved white light interferometry are deeply analyzed. First, the contribution to uncertainty of the different parameters affecting both indices is identified. Afterwards, results are presented for a 1.5 mm thick fused silica sample over a broad spectral range, from 400 to 1000 nm, and the effects that mostly deteriorate the measurement accuracy are established. Finally, the different contributions are quadratically combined to determine the total uncertainty of the two indices

Description

Bibliographic citation

Measurement 187 (2022) 110225

Relation

Has part

Has version

Is based on

Is part of

Is referenced by

Is version of

Requires

Sponsors

The financial support of the Spanish Ministry of Economy and Competitiveness through the coordinated grants MAT2017-89239-C2-1-P is gratefully acknowledged. Moreover, this work was funded by the Xunta de Galicia and FEDER (ED431D 2017/06, ED431E2018/08, GRC 508 ED431C 2020/10)