Numerical simulations of the Epley maneuver with clinical implications

dc.contributor.affiliationUniversidade de Santiago de Compostela. Centro Interdisciplinar de Investigación en Tecnoloxías Ambientais (CRETUS)
dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física de Partículas
dc.contributor.authorArán Tapia, Ismael
dc.contributor.authorSoto Varela, Andrés
dc.contributor.authorPérez Muñuzuri, Vicente
dc.contributor.authorSantos Pérez, Sofía María de la Soledad
dc.contributor.authorArán González, Ismael
dc.contributor.authorPérez Muñuzuri, Alberto
dc.date.accessioned2024-10-30T13:31:25Z
dc.date.available2024-10-30T13:31:25Z
dc.date.issued2024-07
dc.description.abstractObjectives: Canalith repositioning procedures to treat benign paroxysmal positional vertigo are often applied following standardized criteria, without considering the possible anatomical singularities of the membranous labyrinth for each individual. As a result, certain patients may become refractory to the treatment due to significant deviations from the ideal membranous labyrinth, that was considered when the maneuvers were designed. This study aims to understand the dynamics of the endolymphatic fluid and otoconia, within the membranous labyrinth geometry, which may contribute to the ineffectiveness of the Epley maneuver. Simultaneously, the study seeks to explore methods to avoid or reduce treatment failure. Design: We conducted a study on the Epley maneuver using numerical simulations based on a three-dimensional medical image reconstruction of the human left membranous labyrinth. A high-quality micro-computed tomography of a human temporal bone specimen was utilized for the image reconstruction, and a mathematical model for the endolymphatic fluid was developed and coupled with a spherical particle model representing otoconia inside the fluid. This allowed us to measure the position and time of each particle throughout all the steps of the maneuver, using equations that describe the physics behind benign paroxysmal positional vertigo. Results: Numerical simulations of the standard Epley maneuver applied to this membranous labyrinth model yielded unsatisfactory results, as otoconia do not reach the frontside of the utricle, which in this study is used as the measure of success. The resting times between subsequent steps indicated that longer intervals are required for smaller otoconia. Using different angles of rotation can prevent otoconia from entering the superior semicircular canal or the posterior ampulla. Steps 3, 4, and 5 exhibited a heightened susceptibility to failure, as otoconia could be accidentally displaced into these regions. Conclusions: We demonstrate that modifying the Epley maneuver based on the numerical results obtained in the membranous labyrinth of the human specimen under study can have a significant effect on the success or failure of the treatment. The use of numerical simulations appears to be a useful tool for future canalith repositioning procedures that aim to personalize the treatment by modifying the rotation planes currently defined as the standard criteria.
dc.description.peerreviewedSI
dc.identifier.citationArán-Tapia, Ismael; Soto-Varela, Andrés; Pérez-Muñuzuri, Vicente; Santos-Pérez, Sofía; Arán, Ismael; Muñuzuri, Alberto P. Numerical Simulations of the Epley Maneuver With Clinical Implications. Ear & Hearing 45(4):p 1033-1044, July/August 2024. | DOI: 10.1097/AUD.0000000000001493
dc.identifier.doi10.1097/AUD.0000000000001493
dc.identifier.urihttps://hdl.handle.net/10347/37593
dc.issue.number4
dc.journal.titleEarth and hearing
dc.language.isoeng
dc.page.final1044
dc.page.initial1033
dc.publisherAmerican Auditory Society
dc.relation.publisherversionhttps://journals.lww.com/ear-hearing/fulltext/2024/07000/numerical_simulations_of_the_epley_maneuver_with.21.aspx
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectBenign paroxysmal positional vertigo
dc.subjectCanalith repositioning procedure
dc.subjectEpley maneuver
dc.subjectMathematical modeling
dc.subjectNumerical simulations
dc.subjectPersonalized medicine
dc.titleNumerical simulations of the Epley maneuver with clinical implications
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number45
dspace.entity.typePublication
relation.isAuthorOfPublicationc4ec7bed-5f5e-4338-88af-5d0deedbd48b
relation.isAuthorOfPublication693d8d1b-e7ed-40c4-a1ce-ff786d98b9f4
relation.isAuthorOfPublicationfaa7d29e-5643-4d05-b9ab-fa46f344ccc8
relation.isAuthorOfPublicationac82dae1-bab8-4f3d-a37c-d13662246534
relation.isAuthorOfPublication.latestForDiscoveryc4ec7bed-5f5e-4338-88af-5d0deedbd48b

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
numerical_simulations_of_the_epley_maneuver_with.21.pdf
Size:
1.52 MB
Format:
Adobe Portable Document Format