Comparison of Central Corneal Thickness measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography
| dc.contributor.affiliation | Universidade de Santiago de Compostela. Departamento de Física Aplicada | es_ES |
| dc.contributor.author | González Pérez, Javier | |
| dc.contributor.author | Queiruga Piñeiro, Juan | |
| dc.contributor.author | Sánchez García, Ángel | |
| dc.contributor.author | González Méijome, José Manuel | |
| dc.date.accessioned | 2024-02-09T09:31:06Z | |
| dc.date.available | 2024-02-09T09:31:06Z | |
| dc.date.issued | 2018 | |
| dc.description | This is an Accepted Manuscript version of the following article, accepted for publication in Current Eye Research. [González-Pérez J, Queiruga Piñeiro J, Sánchez García Á, González Méijome JM. Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography. Curr Eye Res. 2018 Jul;43(7):866-872]. It is deposited under the terms of the Creative Commons Attribution-NonCommercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. | es_ES |
| dc.description.abstract | Purpose: To compare central corneal thickness (CCT) measured by standard ultrasound pachymetry (USP), and three non-contact devices in healthy eyes. Methods: A cross-sectional study of CCT measurement in 52 eyes of 52 healthy volunteers was done by a single examiner at Ocular Surface and Contact Lens Laboratory. Three consecutive measurements were done by standard USP, non-contact tono-pachymeter, Pentacam corneal topographer, and Anterior Segment Optical Coherence Tomography (AS-OCT). The mean values were used for assessment. The results were compared using multivariate ANOVA, linear regression, and Pearson correlation. Agreement among the devices was analyzed using mean differences and Bland-Altman analysis with 95% limits of agreement (LoA). Finally, reliability was analyzed using intraclass correlation coefficient (ICC). Results: Mean CCT by ultrasound pachymeter, tono-pachymeter, corneal topographer and AS-OCT were 558.9 ± 31.2 µm, 525.8 ± 43.1 µm, 550.4 ± 30.5 µm, and 545.9 ± 30.5 µm respectively. There was a significant positive correlation between AS-OCT and USP (Pearson correlation = 0.957, p < 0.001), corneal topography and USP (Pearson correlation = 0.965, p < 0.001), and corneal topography and AS-OCT (Pearson correlation = 0.965, p < 0.001). There was a lower correlation between CT-1P tono-pachymeter and the other three modalities. Intraclass correlation coefficients show an excellent reliability between pairs except for CT-1P against the other three instruments that were found moderate. Conclusions: CT-1P tono-pachymeter underestimates CCT measurements compared to Scheimpflug system, AS-OCT device, and USP. Mean CCT among USP, Pentacam and AS-OCT were comparable and had significant linear correlations. In clinical practice, these three modalities could be interchangeable in healthy patients. | es_ES |
| dc.description.peerreviewed | SI | es_ES |
| dc.identifier.citation | González-Pérez J, Queiruga Piñeiro J, Sánchez García Á, González Méijome JM. Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography. Curr Eye Res. 2018 Jul;43(7):866-872. doi: 10.1080/02713683.2018.1461910. Epub 2018 Apr 13. | es_ES |
| dc.identifier.doi | 10.1080/02713683.2018.1461910 | |
| dc.identifier.essn | 1460-2202 | |
| dc.identifier.issn | 0271-3683 | |
| dc.identifier.uri | http://hdl.handle.net/10347/32634 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Taylor and Francis Group | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1080/02713683.2018.1461910 | es_ES |
| dc.rights | Creative Commons Attribution-NonCommercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.subject | Central corneal thickness | es_ES |
| dc.subject | Scheimpflug camera | es_ES |
| dc.subject | Anterior segment optical coherence tomography | es_ES |
| dc.subject | Interchangeability | es_ES |
| dc.subject | Non-contact tono-pachymetry | es_ES |
| dc.subject | Ultrasound pachymetry | es_ES |
| dc.title | Comparison of Central Corneal Thickness measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | AM | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 1420ecc5-a082-4e70-8130-44dfeeadeed5 | |
| relation.isAuthorOfPublication.latestForDiscovery | 1420ecc5-a082-4e70-8130-44dfeeadeed5 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2018 Comparison of central corneal thickness.pdf
- Size:
- 940.1 KB
- Format:
- Adobe Portable Document Format
- Description: