Clinical performance of an objective methodology to categorize tear film lipid layer patterns

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Física Aplicadaes_ES
dc.contributor.authorGarcía Resúa, Carlos
dc.contributor.authorPena Verdeal, Hugo
dc.contributor.authorGiráldez Fernández, María Jesús
dc.contributor.authorYebra-Pimentel Vilar, Eva
dc.date.accessioned2024-02-12T13:18:11Z
dc.date.available2024-02-12T13:18:11Z
dc.date.issued2017
dc.description.abstractPurpose: To validate the performance of a new objective application designated iDEAS (Dry Eye Assessment System) to categorize different zones of lipid layer patterns (LLPs) in one image. Material and methods: Using the Tearscopeplus and a digital camera attached to a slit-lamp, 50 images were captured and analyzed by 4 experienced optometrists. In each image, the observers outlined tear film zones identified as a specific LLP. Further, the categorization by the 4 optometrists (observers 1, 2, 3 and 4) was compared with the automatic system included in iDEAS (5th observer). Results: In general, observer 3 was classified as worse than all observers (observers 1, 2, 4 and automatic application, Wilcoxon test, <0.05). The automatic system behaved similarly to the remaining three observers (observers 1, 2 and 4) showing differences only for Open Meshwork LLP when compared with observer 4 (Wilcoxon test, p=0.02). For the remaining two observers (observers 1 and 2) there were not found statistical differences (Wilcoxon test, >0.05). Furthermore, we obtained a set of photographs per LLP category for which all optometrists showed agreement by using the new tool. After examining them, we detected the more characteristic features of each LLP to enhance the description of the patterns implemented by Guillon. Conclusions: The automatic application in the iDEAS framework can provide zones similar to the annotations made by experienced optometrists. Thus, the manual process done by experts can be automated with the benefit of being unaffected by subjective factors.es_ES
dc.description.peerreviewedSIes_ES
dc.identifier.citationGarcía Resúa, C., Pena Verdeal, H., Giráldez, M.J., Yebra-Pimentel Vilar, E. (2017) Clinical performance of an objective methodology to categorize tear film lipid layer patterns, Proceedings of SPIE, vol. 10453es_ES
dc.identifier.doi10.1117/12.2271845
dc.identifier.essn1996-756X
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/10347/32799
dc.language.isoenges_ES
dc.publisherSPIEes_ES
dc.relation.publisherversionhttps://doi.org/10.1117/12.2271845es_ES
dc.rights© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).es_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectLipid layer patternes_ES
dc.subjectTearscope-pluses_ES
dc.subjectTear filmes_ES
dc.subjectInterference phenomenaes_ES
dc.titleClinical performance of an objective methodology to categorize tear film lipid layer patternses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationc3d974d9-f3f1-4d54-b5d1-539f311d9af0
relation.isAuthorOfPublicationa33f1b46-c5e2-417e-99e1-317d1e6e3ff6
relation.isAuthorOfPublication69b318a3-627d-45b7-97fa-d28c31908892
relation.isAuthorOfPublication45eab007-782a-4666-aac6-8c7020f1c661
relation.isAuthorOfPublication.latestForDiscoveryc3d974d9-f3f1-4d54-b5d1-539f311d9af0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017_Garcia-Resua_ProceedingSPIE - COMPLETO - Clinical Performance of an objetive methodology to.pdf
Size:
972.12 KB
Format:
Adobe Portable Document Format
Description:

Collections