Using NS5B Sequencing for Hepatitis C Virus Genotyping Reveals Discordances with Commercial Platforms

dc.contributor.affiliationUniversidade de Santiago de Compostela. Departamento de Microbioloxía e Parasitoloxíaes_ES
dc.contributor.authorChueca, Natalia
dc.contributor.authorRivadulla, Isidro
dc.contributor.authorLovatti, Rubén
dc.contributor.authorReina, Gabriel
dc.contributor.authorBlanco, Ana
dc.contributor.authorFernández Caballero, José Ángel
dc.contributor.authorCardeñoso, Laura
dc.contributor.authorRodríguez Granjer, Javier
dc.contributor.authorFernández Alonso, Miriam
dc.contributor.authorAguilera Guirao, Antonio
dc.contributor.authorÁlvarez, Marta
dc.contributor.authorGalán, Juan Carlos
dc.contributor.authorGarcía, Federico
dc.date.accessioned2024-01-29T12:44:08Z
dc.date.available2024-01-29T12:44:08Z
dc.date.issued2016
dc.description.abstractWe aimed to evaluate the correct assignment of HCV genotypes by three commercial methods—Trugene HCV genotyping kit (Siemens), VERSANT HCV Genotype 2.0 assay (Siemens), and Real-Time HCV genotype II (Abbott)—compared to NS5B sequencing. We studied 327 clinical samples that carried representative HCV genotypes of the most frequent geno/subtypes in Spain. After commercial genotyping, the sequencing of a 367 bp fragment in the NS5B gene was used to assign genotypes. Major discrepancies were defined, e.g. differences in the assigned genotype by one of the three methods and NS5B sequencing, including misclassification of subtypes 1a and 1b. Minor discrepancies were considered when differences at subtype levels, other than 1a and 1b, were observed. The overall discordance with the reference method was 34% for Trugene and 15% for VERSANT HCV2.0. The Abbott assay correctly identified all 1a and 1b subtypes, but did not subtype all the 2, 3, 4 and 5 (34%) genotypes. Major discordances were found in 16% of cases for Trugene HCV, and the majority were 1b- to 1a-related discordances; major discordances were found for VERSANT HCV 2.0 in 6% of cases, which were all but one 1b to 1a cases. These results indicated that the Trugene assay especially, and to a lesser extent, Versant HCV 2.0, can fail to differentiate HCV subtypes 1a and 1b, and lead to critical errors in clinical practice for correctly using directly acting antiviral agentses_ES
dc.description.peerreviewedSIes_ES
dc.description.sponsorshipThis work was supported in part by grants from Fondo de Investigación Sanitaria (PI12/01053, PI15/00713), RD12/0017/006 (Plan Nacional de I+D+I and Fondo Europeo de Desarrollo Regional-FEDER), and PI-0411-2014, Fundación Progreso y salud, Junta de Andalucía. Federico García has received a research extension grant from the Programa de Intensificación de la Actividad de Investigación del Servicio Andaluz de Saludes_ES
dc.identifier.citationChueca N, Rivadulla I, Lovatti R, Reina G, Blanco A, Fernandez-Caballero JA, et al. (2016) Using NS5B Sequencing for Hepatitis C Virus Genotyping Reveals Discordances with Commercial Platforms. PLoS ONE 11(4): e0153754. https://doi.org/10.1371/journal.pone.0153754es_ES
dc.identifier.doi10.1371/journal.pone.0153754
dc.identifier.essn1932-6203
dc.identifier.urihttp://hdl.handle.net/10347/32037
dc.language.isoenges_ES
dc.publisherPLOSes_ES
dc.relation.publisherversionhttps://doi.org/10.1371/journal.pone.0153754es_ES
dc.rights© 2016 Chueca et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are creditedes_ES
dc.rightsAtribución 4.0 Internacional
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleUsing NS5B Sequencing for Hepatitis C Virus Genotyping Reveals Discordances with Commercial Platformses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication6e477f6c-24a1-4722-b59f-699483522575
relation.isAuthorOfPublication.latestForDiscovery6e477f6c-24a1-4722-b59f-699483522575

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2016_plone_chueca_using.pdf
Size:
187.69 KB
Format:
Adobe Portable Document Format
Description: