Development of an analytical methodology based on fabric phase sorptive extraction followed by gas chromatography-tandem mass spectrometry to determine UV filters in environmental and recreational waters
Loading...
Identifiers
Publication date
Advisors
Tutors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier
Abstract
A novel method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been validated for the simultaneous determination of 11 UV filters (ethylhexyl salicylate, benzyl salicylate, homosalate, benzophenone-3, isoamylmethoxycinnamate, 4-methylbenzylidenecamphor, methyl anthranilate, etocrylene, 2-ethylhexylmethoxycinnamate, 2-ethylhexyl p-dimethylaminobenzoate, and octocrylene), in natural and recreational waters. Major experimental parameters affecting FPSE procedure have been optimized to obtain the highest extraction efficiency. Different types and sizes of sol-gel coated FPSE media, sample volume, extraction time, and type and volume of desorption solvent were evaluated. The optimal conditions involved the use of a (2.0 × 2.5) cm2 FPSE device with PDMS based coating for the extraction of 20 mL of water for 20 min. The quantitative desorption of the target compounds was performed with 0.5–1 mL of ethyl acetate. The method was satisfactorily validated in terms of linearity, precision, repeatability and reproducibility. Recovery studies were performed at different concentration levels in real water matrices to show its suitability, obtaining mean values about 90% and satisfactory precision. LODs were at the low ng L−1 in all cases. Finally, the validated FPSE-GC-MS/MS method was applied to different real samples, including environmental water (lake, river, seawater) and recreational water (swimming-pool), where 8 out of the 11 studied compounds were detected at concentrations between 0.12-123 μg L−1. FPSE is proposed as an efficient and simple alternative to other extraction and microextraction techniques for the analysis of UV filters in waters. Since no matrix effects were observed, quantification could be carried out by conventional calibration with standard solutions, without the need to perform the complete FPSE procedure, thus allowing a higher throughput in comparison with other microextraction techniques.
Description
Bibliographic citation
Celeiro, M., Acerbi, R., Kabir, A., Furton, K.G., LLompart, M.(2020). Development of an analytical methodology based on fabric phase sorptive extraction followed by gas chromatography-tandem mass spectrometry to determine UV filters in environmental and recreational waters. "Analytica Chimica Acta: X", vol.4,100038
Relation
Has part
Has version
Is based on
Is part of
Is referenced by
Is version of
Requires
Publisher version
https://doi.org/10.1016/j.acax.2019.100038Sponsors
This research was supported by project UNST10-1E-491 (Infrastructure Program, Ministry of Science and Innovation, Spain). The authors belong to the National Network for the Innovation in miniaturized sample preparation techniques, RED2018-102522-T (Ministry of Science, Innovation and Universities, Spain), to the Galician Competitive Research Group GPC2017/04 and to the CRETUS Strategic Partnership (ED431 2018/01). This study is based upon work from COST Action CA16215. All these programmes are co-funded by FEDER (UE)
Rights
© 2019 Published by Elsevier B.V. This is an open access article under the CC Attribution-NonCommercial-NoDerivatives license